· The large CERaymond coal mills that I worked on were pressurized by the PA Fan. If this is your case, I wonder if the shaft seal is leaking and causing aeration? How does the oil run up hill? I have never seen a slinger used for a vertical shaft! How can you run for an extended time with the external oil pump off?